Technology of power generation -
>80% ADDITIONAL POWER GENERATION
while installed power remains unchanged
Technology of energy saving -
>45% REDUCTION OF ELECTRICITY EXPENSES
while keeping the same level of power consumption
Technology
Alpha-inverter
electric power
generation technology

Global Energy Solutions LLP owns a unique technology that enables to generate additional electric power from any sources of power generation with a minimum guaranteed coefficient of 1.8 and allows our customers to:

  • reduce their electricity expenses by at least 45% while maintaining the same level of electric power consumption; or
  • increase power consumption by at least 80% while keeping installed power capacity unchanged; or
  • increase power generation by at least 80%

The technology is represented by a range of power inverter plants Alpha-Inverter of different rated power.

Functional characteristics of the equipment are confirmed by the highly reputable National University of Oil and Gas "Gubkin University" (https://www.gubkin.ru)


Simplified standard power scheme
For consumer
For power generator
Alpha-inverter
Transmission
1000 kWh555 kWh
Transformer
1000 kWh555 kWh
Electric meter
1000 kWh555 kWh
A
> 45% Reduction of electricity costs while maintaining the same level of electric power consumption > 80% increase in electric power consumption while installed power capacity remains unchanged
> 80% increase in electric power consumption while installed power capacity remains unchanged
1000 kWh1000 kWh
Consumer
Transmission
1000 kWh
Transformer
1000 kWh
Electric meter
1000 kWh
A
> 80% increase in electric power consumption while installed power capacity remains unchanged
1800 kWh
Consumer
Solar/ Wind PP
1000 kWh1000 kWh
A
> 80% increase in power generation while keeping installed power capacity unchanged
> 80% increase in electric power consumption while installed power capacity remains unchanged
1800 kWh1800 kWh
Electric meter
1000 kWh1800 kWh
Transformer
1000 kWh1800 kWh
Transmission

Illustrative example
For Consumer
For power generator
Simplified electrical supply scheme of 1 MWh consumption with Alpha-Inverter (AI1250kVA)
Transformer
10 000 kWh
Electric meter
10 000 kWh
A
18 000 kWh
Consumer
Usual consumption Using AI1250 with a guaranteed coefficient of 1.8 *
Average daily consumption, kWh 18 000 18 000
Daily consumption from power line, kWh 18 000 18 000 / 1.8 = 10 000
Price per 1 kWh, USD 0,1 0,1
Monthly electricity bill, USD 18 000 * 0,1 * 30 = 54 000 10 000 * 0,1 * 30 = 30 000
Monthly savings, USD 24 000
Annual savings, USD 288 000
* Actual coefficient may vary from 1.8 to 3
Simplified power generation for 2 MW solar power plant with Alpha-Inverter
Solar PP
8 800 kWh
A
15 840 kWh
Transformer
15 840 kWh
Transmission
Usual power generation Using of AI2500 with guaranteed 80% rate
Daily generation, kWh 8 000 8 800 * 1.8 = 15 840
Annual generation, kWh 8 800 * 365 = 3 212 000 15 840 * 365 = 5 781 600
Tariff per 1 kWh, USD 0,1 0,1
Monthly electricity bill, USD 8 800 * 0.1 * 365 = 321 200 15 840 * 0.1 * 365 = 578 160
Total additional revenue, USD 256 960
Capacity factor, % 18.35 33.03

FAQ
How does the technology work? Where does the extra power come from?
Alpha Inverter operation is based on the principle of electromagnetic induction. The special conditions created in the internal circuit of the Equipment produce excess inductance, which generates additional energy and a positive energy balance.
Is this technology a technology of reactive power compensation?
No. Alpha-Inverter is not an equipment for compensation of reactive power losses. The technology works with active power and therefore requires cos Phi at least 0.9.
Does the coefficient of 1.8 vary depending on the source of electricity consumption?
We guarantee the minimum coefficient of 1.8 though it may be higher. A distinctive feature of Alpha-Inverter is that the savings with the claimed coefficient occur regardless of the type of consumption source: this can be either a fully active, fully reactive or a mixed intake.
Are there any specific requirements for installation of Alpha-Inverter?
You need to ensure grounding value of not more than 3 Ohm in accordance with IEC 60364-5-54:2011, grounding capacity of not less that 1.5 KAh, power cos phi of a substation is not less than 0.9
Does a company need to get a special approval from the authorities to get AI installed?
No. Installation of AI is similar to use of the energy saving lamps, because AI is installed after an input electric meter.
What is a useful life of your equipment?
20 years.
What is a warranty period for your equipment?
3 years from the commissioning date.
What are the maintenance costs of the equipment?
The equipment does not have any moving parts. Maintenance costs amount to around 1-3% of the respective equipment cost per year.

Equipment
Application
Our equipment is intended for the consumers with a daily consumption starting from 10000 kW per input

Alpha-Inverter models range from 1000 kVA to 2500 kVA

Average useful life of equipment - 20 years

Warranty period - 3 years from the commissioning date

The equipment has the Eurasian Economic Union certificate of conformity:
TR TC 004/2011 «On safety of low-voltage equipment»
TR TC 020/2011 «Electromagnetic compatibility of technical equipment»

Characteristics
  • Rated power1000/1250/1600/2000/2500 kVA
  • Rated voltage0,4 kV
  • Environmental parameters of climatic
    conditions according to IEC 60721-3-4
    4K2
  • Rated frequency50/60 Hz
  • Enclosure protection class IEC 60529 I55
  • Dimensions (LxWxH)2176x1160x1820 mm
  • Total weight1650-1680 kg
  • Sanitary zone around the Equipment1,5 m
  • Operation manual

1
2
3
4
5
6
7
8
9
10
Alpha-inverter composition

PIC microcontrollers and SCADA-bus base control unit

Impulse unit: Cascade impulse generator

Impulse unit: Spark gap control unit

Impulse unit: Transformation unit

Three-phase input meter

Three-phase output meter

Wireless router

Input busbar

Output busbar

Security system

×
How we work
Beginning of collaboration
Quotation
Negotiations and clarification of order details
Contract
Standard schedule for alpha-inverter implemenation
Project stages Period (months)
I II III
1. Information gathering — 5-10 days Selected
2. Production upon receipt of prepayment – 45-50 days Selected Selected
3. Launch, bringing into operation – 7-10 days Selected
Actual implementation schedule depends on the customer’s technical specification
Contact us
Alexey Okatenko
CEO and co-founder Global Energy Solutions LLP

CEO and co-founder Global Energy Solutions LLP

Samal-1, h. 9/2, office 708
Almaty City, A25C9B1
Republic of Kazakhstan

Phone: +7(701) 034 69 15, +7(777) 770 99 33
Email: aokatenko@gesllp.net

Official representative in India
Mr. Jayachandran Elango
Phone: +91 99896 12511
Email: jelango@gesllp.net

Support service
Email: support@gesllp.net

For more information, please use the contact form below and your message will be forwarded to the appropriate person.
×
Message sent